IP66 wp Hands Free Call Point
The stainless steel type A outstation as defined in BS5839-9:2011, and is designed to be used by the public as a disabled refuge call point. The outstation is supplied in a brushed stainless finish with a high contrast red screen print with a rugged red telephone handset behind the push door. A stainless steel bezel is available to allow the outstation to be flushed into a wall reducing the need to stock flush and surface variants.
Disabled Toilet Alarm Kit
The emergency assist alarm call systems within a centralized full duplex voice communication system, providing a single display point for all disabled calls within a building. When a call is made the over-door and cancel units emit a two tone siren with the “Halo” flashing, when the call is acknowledged from the EVCS controller the “Halo” on these units lights steadily and the tone double beeps every 15 seconds to reassure the caller help is on the way. As DTA system is connected to a Master Control panel the plates and cables are fully end of line monitored and battery backed as standard. DTA plates are supplied with a brushed stainless finish and a Blue HALO to aid location.
Master Controllers
Master Controllers are bi-directional, full duplex voice communication system to assist during emergencies in high rise buildings or large sites where radio communication cannot be guaranteed to work due to interference from the fire corona. Master Controllers can accept up to eight lines of outstation, (Type A fixed phones, Type B refuge hands free points, emergency assist alarm point or jack points) as required. The touch-screen layout has four buttons allowing quick access to the main functions, and permanently displaying the number of current calls, alarms and faults.
Benefits
4.3” Full Colour Touch-screen
Integrated Assist Call with acknowledge meeting ADA/BS8300
1.5A EN54-4:A2 PSU
Full Duplex operation
Wall mount enclosure
Lockable handset cover
Expandable from 2 to 512 lines
Inbuilt networking
Technical
Controls : 3 Navigation keys, Touch-screen: 4.3” 272 x 480 x RG
Power Supply and Charger: AC input 230VAC +/- 10% 50/60Hz
Dimensions(mm) 300(W) x 350(H) x 95(D)
Weight 6.5KG / Material Stainless Steel/ Acrylic
Cables : 2x2 core 1.5mm or 2.5mm. Distance: 500m
Standards Compliance: EMC EN55103-1, EN55103-2 LVD EN60950
Product Family BS5839-pt9, BS8300, ADA
Connectivity
Connectivity can be easily and quickly integrated with an existing system that already available.
Downloads
Click to download DatasheetCosting
Please call us at +971 04 421 9920 or email at mail (a) xtec.meExpansion Unit
Expansion Controllers are bi-directional, full duplex voice communication system Allows up 8 lines to be connected. Master Controllers can accept up to eight lines of outstation, (Type A fixed phones, Type B refuge hands free points, emergency assist alarm point or jack points) as required. Allows up 8 lines to be connected. Single 12V 7AH Battery backup built-in. Enclosure mounting does not require any PCB removal.
Benefits
1.5A EN54-4:A2 PSU
Full Duplex operation
Wall mount enclosure
Lockable handset cover
Expandable up-tp 8 lines
Inbuilt networking
Technical
Power Supply and Charger: AC input 230VAC +/- 10% 50/60Hz
Dimensions(mm) 300(W) x 220(H) x 95(D)
Weight 6.5KG / Material Stainless Steel/ Acrylic
Cables : 2x2 core 1.5mm or 2.5mm. Distance: 500m
Standards Compliance: EMC EN55103-1, EN55103-2 LVD EN60950
Product Family BS5839-pt9, BS8300, ADA
Connectivity
Connectivity can be easily and quickly integrated with an existing system that already available.Downloads
Click to download DatasheetCosting
Please call us at +971 04 421 9920 or email at mail (a) xtec.meHands Free Outstations
The stainless steel hands-free type B outstation as defined in BS5839-9:2011, and is designed to be used by the public as a disabled refuge call point.Hands-free outstation is not supplied with a back- box as it can be used with any “MK” style double back-box over 25mm deep. Once the outstation is mounted the supplied sign should be placed adjacent to the outstation to give instructions and identify the point. Excellent speech pickup from microphone due to internal AGC.
Benefits
Braille enhanced Call Button
Stainless Steel as standard
Hands free full duplex operation
High volume ringer
Red status LEDs in Call Button
Green flashing Call Button for location
Flush or surface mount
Fully Monitored to BS5839-9:2011
Fits standard double Socket Back Box (86mm x 146mm)
Technical
Dimensions(mm) 146(W) x 86(H) x 22(D)
Weight 0.4KG / Material Stainless Steel/ Acrylic
Cables : 2x2 core 1.5mm or 2.5mm. Distance: 500m
Standards Compliance: EMC EN55103-1, EN55103-2 LVD EN60950
Product Family BS5839-pt9, BS8300, ADA
Connectivity
Connectivity can be easily and quickly integrated with an existing system that already available.
Downloads
Click to download DatasheetCosting
Please call us at +971 04 421 9920 or email at mail(a)xtec.meFire Telephone EVAC
'Type A' telephone-style outstations are used in emergency evacuation applications. Comprising a telephone handset in a push-to-open or lockable steel cabinet, they are typically located at entrances and fire-fighting lobbies to allow communicate with building control during an emergency. The stainless steel type A outstation as defined in BS5839-9:2011, and is designed to be used by the public as a disabled refuge call point. The outstation is supplied in a brushed stainless finish with a high contrast red screen print with a rugged red telephone handset behind the push door. A stainless steel bezel is available to allow the outstation to be flushed into a wall reducing the need to stock flush and surface variants.
Benefits
Compact Design
Ruggedised Handset
High Volume Ringer
Status LED
20mm Cable Gland knock-out
Telecoil for hearing impaired users
Full Duplex Operation
Fully Compliant to BS5839-9:2011
Magnetic Push Catch
Stainless Steel as standard
Fully Monitored to BS5839-9:2011
Fits standard double Socket Back Box (86mm x 146mm)
Technical
Dimensions(mm) 300(W) x 150(H) x 95(D)
Weight 1.4KG / Material Stainless Steel/ Acrylic
Cables : 2x2 core 1.5mm or 2.5mm. Distance: 500m
Standards Compliance: EMC EN55103-1, EN55103-2 LVD EN60950
Product Family BS5839-pt9, BS8300, ADA
Connectivity
Connectivity can be easily and quickly integrated with an existing system that already available.
{tab title=Design}
Downloads
Click to download DatasheetCosting
Please call us at +971 04 421 9920 or email at mail (a) xtec.meFire Telephone EVAC
'Type A' telephone-style outstations are used in emergency evacuation applications. Comprising a telephone handset in a push-to-open or lockable red steel cabinet, they are typically located at entrances and fire-fighting lobbies to allow communicate with building control during an emergency. Connect to central control equipment using two cores of 1.5mm sq. enhanced fire rated cable.
Hands Free Outstations
'Type B' intercom style outstations offer true hands-free duplex speech to allow anyone in a refuge area to communicate with building control at the touch of a button. Attractively finished in green steel or stainless steel, they includes connections for an optional induction loop system and a general-purpose relay output that closes on activation of the unit. Flush, surface and weatherproof versions are available. Connect to central control equipment using two cores of 1.5mm sq. enhanced fire rated cable.
Line Expansion Unit
Can be connected to an SCU-16 controller to increase its line capacity 16 lines respectively. Can be semi-flush mounted using an AFP385 bezel. Easily interfaced to accessible toilet alarms, PDA audio-frequency induction loop systems, strobes, CCTV activation relays, etc.
Master Controllers
Our Refuge master controllers starts from 4 to 16 line 'Compact' system comprises two wall-mounting master controllers (the CCU-16 and the ECU-16 which can handle 16 and 16 extension lines) as an sixteen-line expansion unit (the ECU-16). Typically located in a building's control room or fire services access point, the CCU-16 and ECU-16 allow emergency personnel to communicate via a telephone-style handset with the system's 'outstations'.