Patient Unit
Patient Control or Patient Unit can be used for nurse call activation button, loudspeaker call via socket with loudspeaker, taking telephone call , control of two lights, easy identification of activation button of calling during the night time (NIGHT BUTTON).
Patient Bed Control
Patient Terminal or Patient Bed Control unit can be used for nurse call activation button, calling ancillary personnel (coffee, food etc.), Discreet call and listening to entertainment programme, loudspeaker call and listening to entertainment programme via socket with loudspeaker. Regulation of volume of entertainment programme, taking telephone call from municipal network, light control, selection of up to 10 entertainment programmes and easy identification of activation button of calling during the night time (NIGHT BUTTON).
Reset Button
Deactivation of emergency calling at place of origin. The button serves primarily for targeted routing of medical personnel to the place from which the EMERGENCY CALL was activated, usually in a bathroom or WC, which is part of a ward. It is located near the door in the bathroom or toilet.
Staff Terminal Control
Staff Control Terminal ensuring supervision of department and end of all types of calls from room with full control, easy operation of color coded control elements marked by symbols. nurse call activation button , activation of, “ALARM“ for calling doctor or other assistance, registration of presence of medical staff in room (green button), registration of presence of nursing staff in room (yellow button), programmable functions for blue doctor button, taking all types of calls from other rooms, - voice call of doctor, taking all types of calls from other rooms, two-way speaker call connection, listening to central announcement from main terminal.
Staff Terminal Unit IP
Staff Terminal ensuring supervision of department and end of all types of calls from room, easy operation of color coded control elements marked by symbols. nurse call activation button , activation of, “ALARM“ for calling doctor or other assistance, registration of presence of medical staff in room (green button), registration of presence of nursing staff in room (yellow button), programmable functions for blue doctor button, taking all types of calls from other rooms. Available in different version like, with sound, display, call etc.
IP ConnectionTerminal
The connection of the master terminal to via LAN (Ethernet). It is fitted in the wiring box and in the wiring frame IFS. In the case of the use of strip terminals, the wires run directly to IP Terminal Box.
Technical Specification
Material: thermoplastic
Colour: white, light blue
Dimensions: 82 x 82 x 23 mm
Weight: 125 g
Master Nurse Terminal IP
The master terminal centralizes the operation of the communication equipment in a room with permanent service, which in most cases is the nurse office. The terminal offers a highly comfortable and clearly arranged graphic user environment linked with simple operation and control of functional buttons directly on the operating graphic touch-screen display.
Main functions
The master terminal centralizes the operation of the communication
Possibility to use unlimited master terminals in the ward
Ward coupling up to 10 wards with availability of all functions of the system
Visualization of unlimited number of calls
Speed dial availability
Discrete speech of nurse with patient and vice versa
Central announcements in the ward
Patient information available on the master terminal screen
Visualization of nurse/personnel presence in the rooms on the master terminal screen
History of calls available on the master terminal
Night mode
LAN communication using latest VoIP technologies with master station Intuitive touch
Possibility to mount it on the wall or place anywhere at the table
RJ-45 interface for connection to Ethernet network
USB port for data backup and software upgrade
Specification
Material: Thermoplastic, stainless. steel
Color: White
Dimensions: 338 x 210-235 x 195mm
Weight: 4475 g
Power supply: Adapter 230V/12V/2A
IP Nurse Call System
IP Nurse Call System brings together care, information, service, organization, and real-time monitoring in hospitals, using a common functional platform. IP-based network technology forms the economical, secure, and extendible structure for all functions and services in the care sector. The distributed architecture ensures the highest degree of flexibility without any limitation. All of the connection options that can be used for a data network at room level if desired.
Master Clock System Controller
Master Clock System Controller
Master Clock System Controller have always been packed with different features with different model. The SMA Series master clocks come with a plethora of standard features such as an (S)NTP input, interfacing with other systems and Daylight Saving Time. Also included is a fully functional web interface that allows you to program the master clock from any Internet connection.
Each master clock has many optional features that are offered a la carte so you can buy the features you need which includes a GPS and a wireless transmitter, we have the answer to virtually any application you may encounter. Master Clock controller collaborates with the Wireless, TalkBack, IP and Wired Systems. Ability to set between 4 or 8 relays where you can program bells to ring. Built-in web interface that allows you to program the master clock from any Internet connection.
Time Zone Master Clock
Master Clock System Time Zone Clock
A Time Zone Clock is a series of clocks that will display the time in your current location as well as other time zones around the world. Installing this Time Zone Clock offers a variety of benefits to many different types of facilities, including hospitals, airports, hotels, corporate offices, government buildings and many more. Time Zone Clock offers all of the unique features our clock systems encompass along with the knowledge of the correct time in your current location and in different time zones around the world.