Corridor lamp
Corridor Light is optical signaling with discrimination of type of call. This has three color-coded lights signaling the state and type of calling in the given place in connection with the room terminal. It is located visibly in the corridor, with the exception of duty rooms, above the door of each ward, separate bathroom and WC.
Call and Reset Button
Call and Reset button allows the activation of certain, and deactivation of all, types of calls within a room directly at a bed and may replace the room terminal in special cases. It is possible to control the LED CL lamp directly from the module or activate emergency calling from the WC. In contrast to the room terminal, this module does not allow the registration of ancillary personnel. It is located near the patient's bed as a part of the bed connection. It can be located at each connection, or only for the first in a series from entry door to a ward it always depends on the customer requirements.
Bed Connection Sounder
The connection with speaker serves for the connection of patient terminals and patient units in wards where wall installation rigs are fitted, and the connection is fitted directly on this installation rig. In combination with the patient terminal it allows the selection of speakerphone voice connection and listening to an entertainment program and discrete connection, with the patient unit only speakerphone listening to program and voice connection.
Bed Connection Unit
This is a switch allowing the bed connection without speaker serves for the connection of the patient terminal only. The version without speaker allows discrete voice connection and listening to audio programs via the patient terminal in wards where wall fitting rigs are installed and the connection is mounted directly on this fitting rig.
Pull Cord
This is a switch allowing the activation of an emergency call in connection with the room terminal. To one room terminal or common bus it is possible to connect in parallel up to 6 elements. It is located close to the toilets and washbasins.
Emergency Call Button
This is a switch allowing the activation of an emergency call in connection with the room terminal. To one room terminal or common bus it is possible to connect in parallel up to 6 elements. It is located close to the toilets and washbasins.
Doctor Call Button
Direct activation of calling “ALARM” with high priority to call doctor directly. It is usually only possible to activate this calling by pressing a combination of buttons on the room terminal so that there can be no abuse or unwanted activation in operation. The button is usually fitted in departments where there are reasons for the immediate activation of this type of call. It serves for the immediate calling of assistance, for example of further medical personnel or a doctor to the given room.
Patient Unit
Patient Control or Patient Unit can be used for nurse call activation button, loudspeaker call via socket with loudspeaker, taking telephone call , control of two lights, easy identification of activation button of calling during the night time (NIGHT BUTTON).
Patient Bed Control
Patient Terminal or Patient Bed Control unit can be used for nurse call activation button, calling ancillary personnel (coffee, food etc.), Discreet call and listening to entertainment programme, loudspeaker call and listening to entertainment programme via socket with loudspeaker. Regulation of volume of entertainment programme, taking telephone call from municipal network, light control, selection of up to 10 entertainment programmes and easy identification of activation button of calling during the night time (NIGHT BUTTON).
Reset Button
Deactivation of emergency calling at place of origin. The button serves primarily for targeted routing of medical personnel to the place from which the EMERGENCY CALL was activated, usually in a bathroom or WC, which is part of a ward. It is located near the door in the bathroom or toilet.